Beyond Laser Systems, LLC — Laser light show projectors manufactured by BLS, Model PURE 5000/10000.

The remote interlock connector, which is required by 21 CFR 1040.10(f)(3), in the remote stop box was not installed the connector or was mechanically installed but not wired. The labels placed on the projectors do not meet requirements specified in 21 CFR 1010.4 (Variances), 21 CFR 1010.2 (Certification), 21 CFR 1010.3 (Identification) and 21 CFR 1040.10 (g)(Labelling requirements). The identification label does not include the date of manufacture as required by 21 CFR 1010.3. The corrective action plan covers three families of laser light show of projectors: DIODE. CLUB and PURE with three different hardware configurations such as the number of the number of RJ45 ports, radiant power of emissions and network configurations. No specific user manuals were provided to each model family as required by 21 CFR 1040.10(h)(1) (Informational requirements (1) User information). The Quality Control test did not validate the manual reset function to enable resumption of laser radiation emission from Class IV laser projectors after an interruption caused using a remote interlock. No supplemental product reports, as required according to 21 CFR 1002.11.

P
Philips North America — SmartPath to dStream for XR and 3.0T Model Numbers (REF): (1) 781270, (2) 782113, (3) 782129;

The potential for component failures in the Gradient Coil of the affected MR systems may act as a heat source with a potential to produce smoke and/or fire.

P
Philips North America — MR 7700 Model Numbers (REF): (1) 782120, (2) 782153;

The potential for component failures in the Gradient Coil of the affected MR systems may act as a heat source with a potential to produce smoke and/or fire.

C
CHETAK NEW YORK LLC — Deep Sprouted Mat 16 oz.

Product tested positive Salmonella .

C
CHETAK NEW YORK LLC — Deep Sprouted Moong 16 oz

Product tested positive Salmonella .

A
AND GO CONCEPTS DBA SALAD AND GO — FG60002 Cucumber Mint Lemonade - point of service product

The firm manufactured and distributed to retailers unpasteurized juice products in violation of 21 CFR 120 Juice HACCP regulations

A
AND GO CONCEPTS DBA SALAD AND GO — FG60005 Blueberry Basil Lemonade

The firm manufactured and distributed to retailers unpasteurized juice products in violation of 21 CFR 120 Juice HACCP regulations

A
AND GO CONCEPTS DBA SALAD AND GO — FG60007 Green Reviver Juice - point of service product

The firm manufactured and distributed to retailers unpasteurized juice products in violation of 21 CFR 120 Juice HACCP regulations

S
Sandoz Inc — Cefazolin for Injection, USP, 1 gram per vial, Sterile, For Intramuscular or Intravenous Use, Rx Only, Manufactured by Sandoz GmbH for Sandoz Inc. Princeton, NJ 08540, NDC: 0781 3451-70 (

Labeling: Label Mix-Up; cartons of Cefazolin for Injection, USP 1 gram were found to contain vials labeled as penicillin G potassium for Injection, USP, 20 million Unit. The vials contained Cefozalin

S
Sandoz Inc — Buffered Penicillin G Potassium for Injection, USP 20,000,000 Units (20 million units), For IV use, Sterile, Rx Only, Manufactured in Austria by Sandoz GmbH for Sandoz Inc. Princeton, NJ

Labeling: Label Mix-Up; Some vials of Cefazolin for Injection, USP 1 gram were incorrectly labeled as penicillin G potassium for Injection, USP, 20 million Unit

L
Lupin Pharmaceuticals Inc. — clomiPRAMINE Hydrochloride Capsules USP 25 mg, 100 count bottles, 5801 Pelican Bay Boulevard, Suite 500, Naples, Florida 34108, NDC# 68180-492-01

Failed Impurities/Degradation Specifications: an out of specification result observed in degradation product test (any unspecified degradation product) during retention sample testing at expiry.

M
Microbiologics Inc — LYFO-DISK, M. Canis Derived from ATCC 36299, packaged as: 1) REF 0894K (6-pack), 2) REF 0894P (2-pack)

KWIK-STIK REF numbers: 0894P, 0894K and LYFO DISK" 0894L may result in failure to recover the target microorganism. All lots of REF 894-76 are impacted.

S
Spiggle & Theis Mt Gmbh — Injection needle, bayonet, Luer-Lock, 1. Model no. 50-353-23, working length 25 cm, total length 31cm, nonsterile; 2. Model no. 50-345-23, working length 24 cm, total l

Affected product show elevated cytotoxicity values. Use of affected injection needles may present a risk of intolerance reaction or allergic reaction.

M
Maquet Cardiopulmonary Gmbh — Sprinter Cart/Sprinter Cart XL Infusion Pole. Component used to hold 2 x 2 kg infusion bags.

Device does not comply with the labeling requirements of international standard IEC 60601-1.

M
Microbiologics Inc — LYFO-DISK, M. Canis Derived from ATCC 36299, packaged as: 1) REF 0894L

KWIK-STIK REF numbers: 0894P, 0894K and LYFO DISK" 0894L may result in failure to recover the target microorganism. All lots of REF 894-76 are impacted.

B
Beckman Coulter Inc. — UIBC (Unsaturated Iron Binding Capacity), REF: OSR61205,

Beckman Coulter identified that the Unsaturated Iron Binding Capacity (UIBC) assay is not meeting their labeled hemoglobin interference claims of no significant interference (i.e., less than 10%) up to 200 mg/dL hemoglobin as indicated in their instructions for use. Initial internal testing confirmed that samples with low UIBC levels failed the claimed hemolysis interference specifications with reported biases up to -43.6 % UIBC when hemolyzed serum samples contained 200 mg/dL hemoglobin.

S
Siemens Healthcare Diagnostics Inc — RAPIDPoint 500 Systems Wash/Waste Cartridge (4 Pack). Material Number: 10329097.

Siemens Healthcare Diagnostics is recalling the RAPIDPoint 500 Systems Wash/Waste Cartridge Lot WW/08925 due to a manufacturing error causing positive and negative bias in Ionized Calcium, Potassium, pH, Chloride, pCO2, Glucose and Lactate analytes and their derivatives. Four complaints were filed related to this event that led to Siemens Healthcare Diagnostics identifying an error in the manufacturing process and initiated corrective actions. Use of the affected device may result in errors during QC which could lead to a delay in patient treatment. If bias generated from this issue is not caught during QC erroneous results may cause temporary or medically reversible adverse health consequences to patients.

W
H
Hamilton Medical AG — Breathing circuit set, coaxial, 1.80 m, with flow sensor and expiratory valve set, REF: 260128, used with HAMILTON-C1, HAMILTON-T1 and HAMILTON-MR1 ventilators.

Ventilator coaxial breathing circuit may have a crack in blue tubing, which is used to deliver fresh gas to the patient. The crack will compromise inspiratory and expiratory flows, leading to partial or complete rebreathing of exhaled gases, which could lead to acute hypercapnia, respiratory acidosis, and if unrecognized organ dysfunction.

B
bioMerieux, Inc. — VITEK¿ 2 Gram-negative AST Test Kits (Cards) containing Colistin formulation cs02n. VITEK¿ 2 is an automated system consisting of instruments, software and reagent cards designed

Potential for false resistant results for Colistin (cs02n) with multi-drug-resistant Pseudomonas aeruginosa and Acinetobacter baumannii complex used in specific cards

B
Beckman Coulter, Inc. — DxI 800 Access Immunoassay Analyzer W/Dual Gantry, Part Number A71457

Beckman Coulter has identified that the UniCel DxI 600/800 systems with linear slide PnP gantries running software versions 5.7 and up faced incorrect PnP X-motor current settings where the PnP X-motor current incorrectly resets to 1.5A (instead of the required 2.0A) because the software overwrites the factory setting during installs or upgrades. This anomaly causes increased PnP motion errors which could lead to delays in reporting patient sample results if unnoticed.

B
Beckman Coulter, Inc. — DxI 600 Access Immunoassay Analyzer W/Spot B, Part Number A71460

Beckman Coulter has identified that the UniCel DxI 600/800 systems with linear slide PnP gantries running software versions 5.7 and up faced incorrect PnP X-motor current settings where the PnP X-motor current incorrectly resets to 1.5A (instead of the required 2.0A) because the software overwrites the factory setting during installs or upgrades. This anomaly causes increased PnP motion errors which could lead to delays in reporting patient sample results if unnoticed.

B
Beckman Coulter, Inc. — DxI 800 Access Immunoassay Analyzer W/Spot B, Part Number A71456

Beckman Coulter has identified that the UniCel DxI 600/800 systems with linear slide PnP gantries running software versions 5.7 and up faced incorrect PnP X-motor current settings where the PnP X-motor current incorrectly resets to 1.5A (instead of the required 2.0A) because the software overwrites the factory setting during installs or upgrades. This anomaly causes increased PnP motion errors which could lead to delays in reporting patient sample results if unnoticed.

C
C SWEET PASTRY LLC — C Sweet Ghouribeh with Pistachios 7 oz., UPC 852664042755

Undeclared soy, contains statement is present but does not list pistachios

← Previous

Page 105 of 158

Next →